Skip to Main Content
IBM Z Software


This portal is to open public enhancement requests against IBM Z Software products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Clear

Ideas

Showing 176 of 9156

Enable MPPs and BMPs to connect to first *available* member of a Db2 data-sharing group

Right now, when using Db2 group-attach feature of IMS, BMP and MPP regions support only connecting to the very first member listed in Db2 group attach name table. If the first member of the group is unavailable, then no connection at all can be ma...
21 days ago in IMS Database Manager / All components 0 Submitted

Add a control option to skip failed elements to DFS3ID00 (zDDL Utility)

For users who are using managed ACB, DFS3UACB(/DFS3PU00) handles failed elements like this: It issues "DFS4470E GSAM DBD DRZ0030 NOT IN DBDLIB. BLDL RC = 4. DBD AND REFERENCING PSBS WERE NOT ADDED TO THE CATALOG." and continues processing the rema...
almost 2 years ago in IMS Database Manager / All components 1 Future consideration

A trace parameter for zSA with a set-table verbose level

This is Tom Wai from TLS (Hong Kong Software Premium Support team) taking care of local z/OS accounts. Recently I had a monthly cases review meeting with HSBC's management team. In their memories, from time to time we suggested different trace set...
about 1 year ago in IBM Z System Automation 1 Not under consideration

SA-internal command HSAET32 should generate a meaningful error message in the event of a problem.

If an SA/NetView is restarted, all HSAET32 are rebuilt and this is logged with ON in netlog. Sometimes this doesn't work and the checker returns a "HSAET32 status ended, RC=1007". so what's the problem? In our case we have some trouble with the ...
about 1 year ago in IBM Z System Automation 0 Future consideration

Show list of changed resources before INGAMS REFRESH

When a new ACF is loaded it is not visible which changes will be activated when this ACF is refreshed. Especially on a production system this is an unwanted situation.Therefor we've made our own rexx. This rexx will check the timestamp in the new ...
over 4 years ago in IBM Z System Automation 1 Future consideration

TESTing INGAMS refresh processing

It would be really helpful to have a way to TEST the INGAMS REFRESH processing without actually performing the policy refresh, after a policy build has been completed. It will help prevent surprises during change window when we perform the actual ...
almost 2 years ago in IBM Z System Automation 2 Future consideration

Disable SA system shutdown automation

When a system is closed, SA automation jumps in on autotask AUTSHUT. This uses PHASE1,2 and 3 customisation, but doesn't allow the functionality to be turned off. We have our own system shutdown processing, and had and shutdown issue, then found t...
about 2 months ago in IBM Z System Automation 0 Submitted

Reduce the disconnect time for BCPII.

I'm not sure whether this idea is in the right workspace. I could also imagine it in the GDPS or CEC workspace. When a switch from the primary SE to the alternate is necessary today (e.g. for an MCL update or reboots), this lasts about 20 minutes....
about 2 months ago in IBM Z System Automation 0 Submitted

"Ignore message ID characters" gets disabled if an AT OVERRIDE is used

It seems unnecessarily restrictive to not allow AT OVERRIDEs when "Ignore message ID characters" is used. This restriction prevents any sort of robust and specific automation definitions from being created without the use of rexx, which seems very...
about 2 months ago in IBM Z System Automation 0 Submitted

Create an IMS type 2 command equivalent to IMS type 2 command "/DIS DBD dbname"

Please Create an IMS type 2 command equivalent to IMS type 1 command : /DIS DBD dbname, according to https://www.ibm.com/docs/en/ims/15.6.0?topic=overview-equivalent-ims-type-1-type-2-commands the IMS type 2 equivalent is QUERY DB NAME(dbname) SHO...
4 months ago in IMS Database Manager / All components 0 Under review