Skip to Main Content
IBM Z Software


This portal is to open public enhancement requests against IBM Z Software products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

Status Not under consideration
Categories Runtime
Created by Guest
Created on Jul 26, 2012

The way CICS manages RM links cause troubles to long running transactions that don't issue syncpoint.

A severe error (code X'2526') has occurred in module DFHERM because of a zeroed RM link token is assigned to a task. This depends by excessive number of SOCKLINK associated to the same UOW. The task owning the UOW is a long running outbound task that never issues user syncpoint. There is a restriction in this area so that each time a socket send is issued an RM ADD_LINK get a new SOCKLINK token, but no RM DELETE_LINK is issued when socket is closed till the end of task. Thus the error is finally generated.
As a bypass to circumvent the problem, the application needs to be modified. It could periodically reattach itself, and go through task termination which will free off the links. This should resolve the problem.

Idea priority Medium
  • Guest
    Reply
    |
    Oct 5, 2015

    Due to processing by IBM, this request was reassigned to have the following updated attributes:
    Brand - Servers and Systems Software
    Product family - Transaction Processing
    Product - CICS Transaction Server

    For recording keeping, the previous attributes were:
    Brand - WebSphere
    Product family - Transaction Processing
    Product - CICS Transaction Server