Skip to Main Content
IBM Z Software


This portal is to open public enhancement requests against IBM Z Software products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Pinned ideas

PINNED Respect $HOME/.config/go/env
After adding eval $(/path/to/goz-env) in .profile, each time I log in to OMVS, I get 3 or 4 lines about $COMPILER_PATH. Can you add config to turn this off, please? Second, even if I have $HOME/.config/go/env (per XDG spec), go env says that `go` ...

All ideas

Showing 8654

Update EVJ120I message to include OPTEXT data.

We have automation code that uses INGTWS/INGOPC command to obtain OPTEXT data for a failing batch job. It would simplify this process if the OPTEXT data was made available on the EVJ120I error message (at the end).
over 1 year ago in IBM Z System Automation 0 Future consideration

Test connection in CICS TG with only SSL

In CICS TG Explorer plugin, the Test connection currently uses the TCP connection as default. We don't have any option to tick the SSL option.
almost 6 years ago in CICS Transaction Gateway / Explorer 1 Not under consideration

Provide possibility to automate fetch of PgmModuleMap.txt

Hi When using different names for loadmodule and first program it's possible to map those with PgmModuleMap.txt ( https://www.ibm.com/docs/en/addi/6.1.1?topic=tasks-adding-files-project-folders ). To be able to automate create/update of the textfi...
over 1 year ago in Application Discovery and Delivery Intelligence / Application Discovery 0 Not under consideration

Need to view 64 Bit Storage in CICS CEDF utilities

The various flavours of the CICS Execution Diagnostic Utility (CEDF) allow me to view storage with 31 bit addresses but increasingly I need to be able to view storage with 64 bit addresses. For example a JCICS program placing data in a container w...
almost 2 years ago in CICS Transaction Server for z/OS / Runtime 1 Future consideration

Prevent needless retry processing in CPSM when a route fails to a clone region

This is a resubmit of RFE 17942. If a request routed by CPSM fails, CICS will retry the request to each AOR in the distribution list. This usually triggers our automation alerts and now with pen-testing, we have the potential for a high volume of ...
almost 6 years ago in CICS Transaction Server for z/OS / Runtime 1 Not under consideration

Database connection there should be filter to see only selected database

Database connection there should be filter to see only selected database not all . Couldn't find any option to put filter . Please find attached screen print. All developer will get benifits.
almost 2 years ago in IBM Developer for z/OS / Other/Unknown 1 Not under consideration

Have Omegamon for z/OS show JES2 spool details for multiple JES2 subsystems

We have a number of LPARs running more than one JES2 subsystem. Currently we can only setup alerts (example: Spool reaching x% full) for the primary JES2 subsystem. The other JES2 subsystem(s) are invisible in Omegamon for z/OS and so no alert can...
over 2 years ago in IBM OMEGAMON for z/OS 1 Future consideration

Need to filter on Jobs that are NP - NOP oper

There is a need to filter on operations that have been set to NP in panel ID EQQSOPFP. This would be much like filtering on operations set to MH (Manual Hold) NP - NOP (no operation). IWSz will set the status of the operation to complete when the ...
about 7 years ago in IBM Z Workload Scheduler 0 Planned for future release

Endpoint Descriptor - New Connection Error Threshold Element

Allow customer-specific settings to define at what point (counter) errors experienced during the endpoint descriptor processing will force an automated system undeploy of the failing endpoint descriptor.
8 months ago in z/TPF Product Family / z/TPF 0 Future consideration

PLI record support for QSAM

Currently the QSAM support does apply only for Cobol, we'd like to see this feature also available on PLI.
almost 2 years ago in Z Virtual Test Platform 1 Not under consideration