Skip to Main Content
IBM Z Software


This portal is to open public enhancement requests against IBM Z Software products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

My ideas: IBM Z System Automation

Showing 155 of 8524

A trace parameter for zSA with a set-table verbose level

This is Tom Wai from TLS (Hong Kong Software Premium Support team) taking care of local z/OS accounts. Recently I had a monthly cases review meeting with HSBC's management team. In their memories, from time to time we suggested different trace set...
11 days ago in IBM Z System Automation 0 Submitted

Increase the number of available Application Symbols (SUBSSYMBOLn/SUBPSYMBOLn), similar to System Automation Symbols (AOCCLONEx)

Both simple and complex environments can be managed more easily through symbol substitution. With additional Application Symbols, a more tailored approach to automation management can be achieved, reducing administration efforts through reusable d...
6 months ago in IBM Z System Automation 3 Future consideration

To see and have confirmation for all the dependency tree for the STOP command in the INGLIST panel at a group level

To see and have confirmation for all the dependency tree for the STOP (INGREQ)command in the INGLIST panel at a group level as the SUSPEND ( INGSUSPD ) command does. It makes no sense to be able to see all the dependency tree for the SUSPEND comma...
19 days ago in IBM Z System Automation 0 Submitted

SA-internal command HSAET32 should generate a meaningful error message in the event of a problem.

If an SA/NetView is restarted, all HSAET32 are rebuilt and this is logged with ON in netlog. Sometimes this doesn't work and the checker returns a "HSAET32 status ended, RC=1007". so what's the problem? In our case we have some trouble with the ...
about 2 months ago in IBM Z System Automation 0 Under review

Extend the Application Class concept to other applicable resource types, such as Application Groups and Monitor Resources.

Q. Why is it useful? A. Reduces time and effort fulfilling "customer" (e.g. Support and Operation staff) requests. Q. Who would benefit from it? A. Both automation administrators and their customers: Administrators benefit by quickly inheriting pr...
4 months ago in IBM Z System Automation 1 Not under consideration

TESTing INGAMS refresh processing

It would be really helpful to have a way to TEST the INGAMS REFRESH processing without actually performing the policy refresh, after a policy build has been completed. It will help prevent surprises during change window when we perform the actual ...
9 months ago in IBM Z System Automation 2 Future consideration

Show list of changed resources before INGAMS REFRESH

When a new ACF is loaded it is not visible which changes will be activated when this ACF is refreshed. Especially on a production system this is an unwanted situation.Therefor we've made our own rexx. This rexx will check the timestamp in the new ...
over 3 years ago in IBM Z System Automation 1 Future consideration

SDF Re-Sev/Re-Color of Existing Captured Message

When using SDF as a monitoring platform, it would be beneficial to mark a captured message as "acknowledged" by changing the color of it on the screen without deleting it entirely, so that it can be followed up on or reports made later. At this ti...
11 months ago in IBM Z System Automation 0 Not under consideration

Dynamic Domain Assignment for NetView Workstations

Objective: Enable the capability to dynamically update the domain assignment of a NetView workstation. This functionality should override the existing assignment set via the System Automation (SA) policy, allowing for temporary workload redistribu...
2 months ago in IBM Z System Automation 0 Under review

Supporting Larger Screen Sizes / Logmodes for NetView / System Automation Panels e.g. INGLIST

Hello NetView / SA Team, currently we are migrating from IBM AF/Operator to NetView SA at our side. And during this migration more and more inquiries are arriving that NetView only displays 62 rows at the most panels (e. g. INGLIST, DISPINFO, and ...
about 4 years ago in IBM Z System Automation 2 Future consideration