Skip to Main Content
IBM Z Software


This portal is to open public enhancement requests against IBM Z Software products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Pinned ideas

PINNED Respect $HOME/.config/go/env
After adding eval $(/path/to/goz-env) in .profile, each time I log in to OMVS, I get 3 or 4 lines about $COMPILER_PATH. Can you add config to turn this off, please? Second, even if I have $HOME/.config/go/env (per XDG spec), go env says that `go` ...

All ideas

Showing 8508

Sample code for zWS user exits (EQQUXnnn) should allow a TRACE for input parameters and return codes

For sample exit code provided in SEQQSAMP or generated from the exit workbench, it would help to be able to turn on a trace which lists the input parameters (normally pointed to via register 1) and the return code used to leave the exit, as this i...
about 1 year ago in IBM Z Workload Scheduler 0 Planned for future release

TLVLOG output

It would be useful to create another way of Dataset to collect the output of TLVLOG. This new way could allow to collect it in several datasets that would avoid to have a huge sequential dataset with all the TLVLOG from long time. For example, a GDG.
over 2 years ago in IBM CL/SuperSession for z/OS / Runtime 2 Planned for future release

Omegamon for z/OS needs to adjust the skip&count formula

The Omegamon for z/OS skip&count formula being used to determine which TCPIP port various Omegamon components bind to needs to be adjusted so the range of ports selected are in a more refined group of ports instead of spread out across the 65K...
over 2 years ago in IBM Tivoli Management Services on z/OS 2 Not under consideration

(TPFUG/Visa) Add ASCII/Text transfer support to the SFTP server

Currently we are using FTPS support where clients can use both binary and text options while sending files to zTPF. The SFTP support provided only support binary transfers and we would like to be able to offer the ASCII/text option.
4 months ago in z/TPF Product Family / z/TPF 2 Future consideration

Design an easier way to send IBM E3270UI program check data

Currently when the E3270UI takes a program check, the PC data is displayed on-screen, and thus the user is forced to create a screen shot and attached it to a case. For both the users and IBM, issue reporting would be much easier, if E3270UI progr...
7 months ago in IBM Tivoli Management Services on z/OS 1 Not under consideration

Support for Cobol stored procedure in IDz 16

When moving from IDz 15 with data studio plugin to IDz 16 with built-in DB2 support we are missing the support to see, execute and debug Cobol stored procedure trough IDz UI. It would be easier for the developer to execute it as it's supposed to b...
7 months ago in IBM Developer for z/OS / Debugger 1 Future consideration

Provide Capability to Write to SYSLOG

ZOAU would benefit from providing a standard mechanism to write a message to the z/OS system log. In automated processes, it is often imperative to indicate progress or the motivation for the process or even indicate that a process is taking place...
over 1 year ago in Z Open Automation Utilities 2 Future consideration

Initialize Cobol Language Environment

The product provides the capability to be customized with user exits. Since programming user exits with cobol is not a question of performance any more, they get rewriten from assembler programming language to cobol. Today, it is mandatory to crea...
over 3 years ago in IBM Z Workload Scheduler 1 Not under consideration

Support exclude feature for REXX MATCH() function

I need to exclude one or more item from a list to suppress an alert. So I would like a MATCH if something is NOT in the string. In my current situation I automate CNZ4200I (https://www.ibm.com/docs/en/zos/2.5.0?topic=messages-cnz4200i), but I need...
4 months ago in IBM Z NetView 0 Future consideration

Provide a DELETE option for the STOP SECONDARY, and a NOCOPY option for the START SECONDARY script statements

As an MGM4SITE environment with external LCP, we have regular resiliency tests where we failover from one region to the other (REG-A to REG-B). When we do this we have to terminate the copy to the LCP source disk in the old recovery region (REG-B)...
over 1 year ago in GDPS 0 Future consideration