Skip to Main Content
IBM Z Software


This portal is to open public enhancement requests against IBM Z Software products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.

ADD A NEW IDEA

Clear

COBOL Compilers

Showing 299 of 9153

IBM Enterprise COBOL V6R4+ - Compilation directive to inform the compiler of the end of sequential code execution (call to exit / abend routine)

Hi, We have observed that compiler optimization, particularly PERFORM inlining, can be disrupted by certain constructs in the COBOL source code: EXEC CICS RETURN EXEC CICS HANDLE ABEND LABEL CALL to subprogram without expected return, (abend...
19 days ago in COBOL Compilers / z/OS 0 Submitted

IBM Enterprise COBOL V6R4+ - Review of SQL coding rules when using the Db2 coprocessor integrated into the compiler

Hi, Based on our tests, when using the Db2 coprocessor integrated into the COBOL compiler, it is possible to declare an SQL cursor that uses host variables before those host variables are declared . This restriction should only apply to the use of...
21 days ago in COBOL Compilers / z/OS 0 Submitted

Port STCK functions from PL/I to COBOL

Hello. COBOL provides intrinsic functions to get date in time in formatted format. I need to also get the STCK (and/or STCKE) values in bin/hexadecimal. PL/I has these features : pex PLISTCK(val) to put the STCK value in val. Is it possible to por...
over 1 year ago in COBOL Compilers / z/OS 1 Future consideration

SECTION name special register

A common challenge in CBL development is the need to add program references in error handling including of course the Procedure Section where the issue has originated from. Developers often manage to incorrectly set this, the classic invalid metho...
3 months ago in COBOL Compilers / z/OS 4 Needs more information

IBM Enterprise COBOL - Suspected error in the usage example in the documentation of the CURRENT-DATE function

Hi, The Language Reference documentation for the CURRENT-DATE function describes a receiving structure with a WS-DIFF-FROM-GMT field declared in S9(4) DISPLAY. By default, signed fields in DISPLAY format are zone-signed, and therefore the field wi...
about 1 month ago in COBOL Compilers / z/OS 2 Under review

Fail gracefully if SYSMDECK undefined or wrongly defined

With 5655-EC6 IBM Enterprise COBOL for z/OS 6.4.0, if SYSMDECK is omitted or defined to SYSOUT=*, the compiler fails with an assertion failure: Assertion failed at ../../ibm/env/ListingAgent.cpp:6191: 0 Could not open source DD:SYSMDECK TR_MvsCall...
3 months ago in COBOL Compilers / z/OS 1 Is a defect

Messages IGZ0201x to be written on syslog too

When a COBOL file definition does not match in record length with the JCL job, then it is running with high CPU (looping). At the moment the message IGZ0201W (A file attribute mismatch was detected. File ... in program ... had a record length of x...
6 months ago in COBOL Compilers 3 Future consideration

A new compilation option (rule) DISPLAYCHECK is required

Dear Madam/Sir, In the frame of ensuring enhanced code quality, we would like to implement a new COBOL compiler option (rule) so an error or warning to be issued in case of existing DISPLAY statements in a program. The new parameter could be DISPL...
9 months ago in COBOL Compilers / z/OS 4 Future consideration

IBM Enterprise COBOL - Add a report of lines impacted by the REPLACE compiler directive

Hi, The REPLACE compiler directive allows replacements of COBOL source text, a priori after processing the COPY directives: from the point where it is declared until the end of the source code, or until the REPLACE OFF directive. However, it...
about 2 months ago in COBOL Compilers / z/OS 1 Not under consideration

IBM Enterprise COBOL - Display ISPF statistics ID information in COPY/BASIS cross-references

Hi, The COPY/BASIS cross-references display ISPF statistics for copies from PDS: creation date, modification date, and time. We would like the ISPF statistics ID information to also be included in the COPY/BASIS cross-references.--> We use this...
about 2 months ago in COBOL Compilers / z/OS 1 Future consideration